Lamotte 2020we turbidity meter manual






















EPA COMPLIANCE The we meter meets or exceeds EPA design specifications for NPDWR and NPDES turbidity monitoring programs as specified by the USEPA method ISO Compliance This wi meter meets or exceeds ISO design criteria for quantitative methods of turbidity using optical turbidimeters as specified by ISO CE COMPLIANCE The we . Lamotte we Portable Turbidity Meter Industry-leading precision, sensitivity, and dependability in one of the most innovative handheld meters available on the market! • Waterproof to IP67 • Lithium rechargeable batteries • USB port • 7 languages • Backlit display • EAP and ISO versions Turbidity Specifications. The we/wi has two different turbidity calibrations, formazin and Japan Standard. The formazin calibration is the EPA and ISO approved method of calibrating nephelometers. This calibration can be used with user prepared formazin standards or commercially purchased formazin standards. LaMotte Company approved AMCOTM standards labeled for.


This wi meter meets or exceeds ISO design criteria for quantitative methods of turbidity using optical turbidimeters as specified by ISO The we and wi meters have been independently tested and have earned the European CE Mark of compliance for electromagnetic compatibility and safety. LaMotte EPA. e i Portable Turbidity Meters. The newly redesigned combines an advanced microprocessor with a patent-pending optical chamber resulting in higher accuracy and a wider range. The multi-detector optical configuration assures long term stability and minimizes stray light and color interferences. The SMARTLink 3 software allows test data to be transferred from a LaMotte instrument to a personal computer. The software relates a set of test results to a particular testing site and date. It gives the user the ability to input site names and unique ID numbers into a table for reference when managing.


The has two different turbidity calibrations, formazin and Japan Standard. The formazin calibration is the EPA and ISO approved method of calibrating nephelometers. This calibration can be used with user prepared formazin standards or commercially purchased formazin standards. LaMotte Company approved AMCOTM. The t meter meets or exceeds EPA design specifi cations for NPDWR and NPDES turbidity monitoring programs as specifi ed by the USEPA method ISO COMPLIANCE This i meter meets or exceeds ISO design criteria for quantitative methods of turbidity using optical turbidimeters as specifi ed by ISO CE COMPLIANCE. How to calibrate and use the LaMotte we/wi Turbidity www.doorway.ru more information on the LaMotte /we/wi Turbidity Meter, visit us at www.doorway.rue.

0コメント

  • 1000 / 1000